Appendix
- 340 -
12
Para. No. Para. Name Setting Range Default Property Page
A7-08 Setting running command via the
user programmable card
0: No command
1: Forward run
2: Reverse run
3: Forward jog
4:Reverse jog
5: Coast to stop
6: Decelerate to stop
7: Fault reset
0
ƿ
1
7
5
A7-09 Setting fault via the user
programmable card
0: No fault
80 to 89: fault code
0
ƿ
1
7
5
Group A8: Point-point Communication
A8-00 Point-point communication 0: Disabled
1: Enabled
0
ƿ
1
7
6
A8-01 Master or slave selection 0: Master
1: Slave
0
ƿ
1
7
6
A8-02 Selection of action of the slave in
point-point communication
000 to 111
Whether to send fault
information to master
when a fault occurs
0: No
1: Yes
Whether to follow
master command
0: No
1: Yes
Whether to alarm when
it becomes offline
0: No
1: Yes
011
ƾ
1
7
7
A8-03 The slave received data 0: Output frequency
1: Frequency reference
0
ƿ
1
7
7
A8-04 Zero offset of received data
-100.00 to 100.00
0.00
ƿ
1
7
7
A8-05 Gain of received data
-10.00 to 10.00
1.00
ƿ
1
7
7
A8-06 Point-point communication
interruption detection time
0.0s to 10.0s
1.0s
ƿ
1
7
7
A8-07 Master data sending cycle in
point-point communication
0.001s to 10.000s
0.001s
ƿ
1
7
7
A8-08 Zero offset of receiving data
(frequency)
-100.00% to 100.00%
0.00%
ƾ
-
A8-09 Gain of receiving data (frequency)
-10.00 to 100.00
1.00
ƾ
-
A8-10 5XQDZD\SUHYHQWLRQFRHI¿FLHQW
0.00% to 100.00%
10.00%
ƾ
-
A8-11 Window width
0.20 to 10.00 Hz
0.50 Hz
1
7
7
Group AC: AI/AO Correction
AC-00 AI1 measured voltage 1 -10.00 to 10.000 V Factory-
corrected
ƿ
-
AC-01 AI1 displayed voltage 1 -10.00 to 10.000 V Factory-
corrected
ƿ
-
AC-02 AI1 measured voltage 2 -10.00 to 10.000 V Factory-
corrected
ƿ
-