5 Parameter Table
- 33 -
Group F6: Start/Stop Control
Para� No� Para� Name Setting Range Unit Default Commission
F6-00 Start mode 0: Direct startup
1: Reserved
2: Pre-excited startup (asynchronous motor)
N�A� 0
F6-01 Mode of catching a
spinning motor
0: From stop frequency
1: From zero speed
2: From max� frequency
N�A� 0
F6-02 Speed of catching a
spinning motor
1 to 100 N�A� 20
F6-03 Startup frequency 0�00 to 10�00 Hz 0�00
F6-04 Startup frequency active
time
0�0 to 100�0 s 0�0
F6-05 DC injection braking
1 level/Pre-excitation
level
0 to 100 % 50
F6-06 DC injection braking
1 active time/Pre-
excitation active time
0�0 to 100�0 s 0�0
F6-07 Acceleration/
Deceleration mode
0: Linear mode
1: S-curve mode A
2: S-curve mode B
N�A� 0
F6-08 Time proportion of
S-curve start segment
0�0 to (100�0 minus F6-09) % 30�0
F6-09 Time proportion of
S-curve end segment
0�0 to (100�0 minus F6-08) % 30�0
F6-10 Stop mode 0: Decelerate to stop
1: Coast to stop
N�A� 0
F6-11 DC injection braking 2
frequency threshold
0�00 to 10�00 Hz 0�00
F6-12 DC injection braking 2
delay time
0�0 to 100�0 s 0�0
F6-13 DC injection braking 2
level
0 to 100 % 50
F6-14 DC injection braking 2
active time
0�0 to 100�0 s 0�0
F6-15 Reserved - - -
F6-18 Catching a spinning
motor current limit
30 to 200 % Model
dependent
F6-21 Demagnetization time 0�00 to 5�00 s Model
dependent
F6-22 Min� output frequency 0�00 to F6-11 Hz 0�00
F6-23 Factory reserved 1 to 100 N�A� 10