6. Description of Parameters                                                                                                                   
- 98 -
 
■
Pulse Reference (DI5)
Frequency reference is input by means of DI5 (high-speed pulse). Signal specification 
of pulse reference is 9 to 30 V (voltage range) and 0 to 100 kHz (frequency range). The 
corresponding value 100% of pulse reference corresponds to the value of F0-10 (max. 
frequency).
Main frequency reference set via pulse reference and pulse output of the FM 
terminal (F5-00 = 1) cannot be used simultaneously.
F4-28 to F4-32 set relationship between pulse input (from DI5 only) and corresponding 
percentage. It has the same function and usage as AI curve 1 does. Refer to 
S
t
e
p
 
1
:
 
S
e
t
 
A
I
 
c
u
r
v
e
.
Function Code Parameter Name Setting Range Default
F4-28
Pulse min. input 0.00 kHz to F4-30 0.00 kHz
F4-29
Corresponding percentage 
of pulse min. input
-100.00% to 100.0% 0.0%
F4-30
Pulse max. input F4-28 to 50.00 kHz 50.00 kHz
F4-31
Corresponding percentage 
of pulse max. input
-100.00% to 100.0% 100.0%
F4-32
Pulse lter time 0.00s to 10.00s 0.10s
Figure 6-19 Pulse input at DI5 to control frequency reference
Note: 
100.0% corresponds to 
max. frequency (F0-10).
DI5
Use pulse signals to control 
frequency reference
 (valid for DI5 only)
COM
Final 
frequency 
reference
Select main frequency 
reference as final 
frequency reference.
Set the relationship between 
the pulse input (from DI5 only) 
and the corresponding 
percentage via F4-28 to F4-32.
Select pulse as main 
frequency reference 
setting channel.
F0-07 (units 
position) = 0
F4-33 (hundreds 
position) = 2
F0-03 = 5