Commissioning and Trial Run
114
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
A1‑04 41220 VDI5 function
selection
Same as A1‑00 0 Modifiable
only at stop
A1‑05 41221 VDI state setting mode Ones:
0: Set by A1‑06
1: DO state
2: DI state
Tens:
0: Set by A1‑06
1: DO state
2: DI state
Hundreds:
0: Set by A1‑06
1: DO state
2: DI state
Thousands:
0: Set by A1‑06
1: DO state
2: DI state
Ten thousands:
0: Set by A1‑06
1: DO state
2: DI state
0 Modifiable
only at stop
A1‑06 41222 VDI state setting Ones:
0: Invalid
1: Valid
Tens:
0: Invalid
1: Valid
Hundreds:
0: Invalid
1: Valid
Thousands:
0: Invalid
1: Valid
Ten thousands:
0: Invalid
1: Valid
0 Modifiable
in any states
A1‑07 41223 Function selection for
AI1 used as DI
Same as F4‑01 0 Modifiable
only at stop
A1‑08 41224 Function selection for
AI2 used as DI
Same as F4‑01 0 Modifiable
only at stop
A1‑09 41225 Function selection for
AI3 used as DI
Same as F4‑01 0 Modifiable
only at stop