Commissioning and Trial Run
‑115‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
A1‑10 41226 Active state selection
for AI used as DI
Ones:
0: Active high
1: Active low
Tens:
0: Active high
1: Active low
Hundreds:
0: Active high
1: Active low
0 Modifiable
only at stop
A5‑00 42240 DPWM switchover
frequency upper limit
0.0050.00 Hz 12.00 Hz Modifiable
in any states
A5‑01 42241 PWM modulation
pattern
0: Asynchronous
modulation
1: Synchronous
modulation
0 Modifiable
in any states
A5‑02 42242 Dead zone
compensation
0: Disabled
1: Enabled
1 Modifiable
only at stop
A5‑03 42243 Random PWM depth 010 0 Modifiable
in any states
A5‑04 42244 Fast current limit 0: Disabled
1: Enabled
0 Modifiable
in any states
A5‑05 42245 Sampling delay 113 5 Modifiable
in any states
A5‑06 42246 Undervoltage
threshold
150.0455.0 V Single‑phase
200 V: 200.0
V; Three‑
phase 400 V:
350.0 V
V Modifiable
in any states
A5‑07 42247 SVC optimization
selection
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
1 Modifiable
only at stop
A6‑00 42496 Curve 4 minimum
input
‑10.00 V to +10.00 V 0.00 V Modifiable
in any states
A6‑01 42497 Corresponding
percentage of curve 4
minimum input
‑100.0% to +100.0% 0.0 % Modifiable
in any states
A6‑02 42498 Curve 4 inflection 1
input
‑10.00 V to +10.00 V 3.00 V Modifiable
in any states
A6‑03 42499 Corresponding
percentage of curve 4
inflection 1 input
‑100.0% to +100.0% 30.0 % Modifiable
in any states
A6‑04 42500 Curve 4 inflection 2
input
‑10.00 V to +10.00 V 6.00 V Modifiable
in any states
A6‑05 42501 Corresponding
percentage of curve 4
inflection 2 input
‑100.0% to +100.0% 60.0 % Modifiable
in any states