Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F4‑28 62492 DI5 inactive delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F4‑29 62493 DI6 inactive delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F4‑30 62494 DI7 inactive delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F4‑31 62495 DI8 inactive delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F4‑32 62496 DI (DI1 to DI5) active
mode selection
Ones: DI1 active mode
Tens: DI2 active mode
Hundreds: DI3 active mode
Thousands: DI4 active
mode
Ten thousands: DI5 active
mode
0: Active low
1: Active high
0 Modifiable
in any states
F4‑33 62497 DI (DI6 to DI8) active
mode selection
Ones: DI6 active mode
Tens: DI7 active mode
Hundreds: DI8 active mode
0: Active low
1: Active high
0 Modifiable
in any states
F5‑00 62720 DO1/RO1 hardware
source
0: No selection
1: Power supply unit DIO1
2: Power supply unit DIO2
3: Power supply unit DIO3
4: Power supply unit DIO4
5: Power supply unit RO1
101: Expansion card 1
DO1/RO1
102: Expansion card 1
DO2/RO2
103: Expansion card 1
DO3/RO3
104: Expansion card 1
DO4/RO4
105: Expansion card 1
DO5/RO5
106: Expansion card 1
DO6/RO6
107: Expansion card 1
DO7/RO7
108: Expansion card 1
DO8/RO8
201: Expansion card 2
DO1/RO1
0 Modifiable
only at stop