Commissioning and Trial Run
‑43‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F5‑09 62729 DO5/RO5 function
selection
Same as F5‑01 0 Modifiable
only at stop
F5‑10 62730 DO1/RO1 active delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑11 62731 DO2/RO2 active delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑12 62732 DO3/RO3 active delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑13 62733 DO4/RO4 active delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑14 62734 DO5/RO5 active delay 0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑15 62735 DO1/RO1 inactive
delay
0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑16 62736 DO2/RO2 inactive
delay
0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑17 62737 DO3/RO3 inactive
delay
0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑18 62738 DO4/RO4 inactive
delay
0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑19 62739 DO5/RO5 inactive
delay
0.00s to 600.00s 0.00 s Modifiable
in any states
F5‑20 62740 DO active mode
selection
Ones: DO1/RO1 active
mode selection
Tens: DO2/RO2 active
mode selection
Hundreds: DO3/RO3 active
mode selection
Thousands: DO4/RO4
active mode selection
Ten thousands: DO5/RO5
active mode selection
0: Active high
1: Active low
0 Modifiable
in any states
F5‑21 62741 Circuit breaker action
threshold
01000 V Single‑phase
220 V: 330 V;
Three‑phase
380 V: 570 V
V Modifiable
in any states
FA‑00 64000 5th (latest) fault code 0 Modification
prohibited
FA‑01 64001 5th fault subcode 0 Modification
prohibited
FA‑02 64002 Bus voltage upon 5th
fault
0.0 V Modification
prohibited