Commissioning and Trial Run
‑44‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
FA‑03 64003 Heatsink temperature
upon 5th fault
‑ 0 °C Modification
prohibited
FA‑04 64004 Ambient temperature
upon 5th fault
‑ 0 °C Modification
prohibited
FA‑06 64006 Grid voltage Usr upon
5th fault
‑ 0 V Modification
prohibited
FA‑07 64007 Grid voltage Ust upon
5th fault
‑ 0 V Modification
prohibited
FA‑08 64008 Grid voltage Utr upon
5th fault
‑ 0 V Modification
prohibited
FA‑09 64009 Three‑phase
unbalance factor
upon 5th fault
‑ 0.00 % Modification
prohibited
FA‑10 64010 DI state upon 5th
fault
‑ 0 ‑ Modification
prohibited
FA‑11 64011 DO/RO state upon 5th
fault
‑ 0 ‑ Modification
prohibited
FA‑12 64012 Stop command sent
by power supply unit
upon 5th fault
1: Ready to run
2: Coast to stop
3: Stop according to preset
mode
0 ‑ Modification
prohibited
FA‑13 64013 Total power‑on time
(in hours) upon 5th
fault
‑ 0 h Modification
prohibited
FA‑14 64014 Total power‑on time
(in minutes) upon 5th
fault
‑ 0 min Modification
prohibited
FA‑15 64015 Total power‑on time
(in seconds) upon 5th
fault
‑ 0 s Modification
prohibited
FA‑20 64020 4th (2nd latest) fault
code
‑ 0 ‑ Modification
prohibited
FA‑21 64021 4th fault subcode ‑ 0 ‑ Modification
prohibited
FA‑22 64022 Bus voltage upon 4th
fault
‑ 0.0 V Modification
prohibited
FA‑23 64023 Heatsink temperature
upon 4th fault
‑ 0.0 °C Modification
prohibited
FA‑24 64024 Ambient temperature
upon 4th fault
‑ 0.0 °C Modification
prohibited
FA‑26 64026 Grid voltage Usr upon
4th fault
‑ 0.0 V Modification
prohibited
FA‑27 64027 Grid voltage Ust upon
4th fault
‑ 0.0 V Modification
prohibited