6 Parameter Description
- 
248
 -
Function 
Code
Name Setting Range Default Unit Property
FC-02  0.50 to 10.00 1.00 -
★
FC-03
Overload pre-warning 
50 to 100 80 %
★
The FC-02 reference quantity is motor overload current. After detecting that the 
output current reaches (FC-02 x Rated motor current) and the duration lasts the time 
motor overload.
The FC-03 reference quantity is motor overload current. After detecting that the 
output current exceeds (FC-03 x Rated motor current) and the duration lasts the time 
Function 
Code
Name Setting Range Default Unit Property
FC-04 Opposite door selection 0 to 3 0 -
★
Fb-00 is used to set the number of door machine(s).
Set it to 1 if there is only one door, and 2 if there are double doors.
FC-04 is used to set opposite door-related control function. The values are as follows:
 
■
0: Simultaneous control
 
■
1: Hall call independent, car call simultaneous
 
■
2: Hall call independent, car call manual control
 
■
3: Hall call independent, car call independent
Function 
Code
Name Setting Range Default Unit Property
FC-11 11
th
 fault code 0 to 9999 0 - 
FC-12 11
th
 fault subcode 0 to 65535 0 - 
FC-13 11
th
 fault month and day 0 to 1231 0 MM.DD 
FC-14
11
th
 fault hour and 
minute
0 to 23.59 0 HH.MM 
FC-15 21
st
 fault code 0 to 9999 0 - 
FC-16 21
st 
fault subcode 0 to 65535 0 - 
FC-17 21
st
 fault month and day 0 to 1231 0 MM.DD 
FC-18
21
st
 fault hour and 
minute
0 to 23.59 0 HH.MM 
FC-207 60
th
 fault code 0 to 9999 0 - 
FC-208 60
th
 fault subcode 0 to 65535 0 -