1 Product Information
- 
30
 -
1.4 Technical Specications
Item 
Input power 
supply
Phase number, 
voltage, and frequency
200 V class: single-phase 220 V to 240 V, 50/60 Hz
400 V class: three-phase 380/400/415/440/460 V, 50/60 
Hz
Allowed voltage 
change
-15% to +10%
Allowed frequency 
change
-5% to +5%
Capacity to withstand 
transient voltage drop 
200 V class:
The system continues to run at over 150 VAC. When 
the voltage is reduced to below 150 VAC from the rated 
input state, undervoltage protection is enabled after 
the system continues to run for 15 ms.
400V class:
The system continues to run at over 300 VAC. When 
the voltage is reduced to below 300 VAC from the rated 
input state, undervoltage protection is enabled after 
the system continues to run for 15 ms.
Basic features
Maximum number of 
Elevator running 
speed
Number of elevators in 
parallel/group mode
Communication mode CAN bus serial communication
Operation functions Refer to product functions in introduction.