7 Troubleshooting
- 
266
 -
7.3 Description of Fault Levels
The NICE3000
new
 has almost 70 pieces of alarm information and protective functions. 
It monitors various input signals, running conditions and feedback signals. If a fault 
occurs, the system implements the relevant protective function and displays the fault 
code.
The controller is a complicated electronic control system and the displayed fault infor-
are handled according to the following table.
Fault Levels
Fault Level Fault State Solution
Level 1
 
◆
Display the fault code.
 
◆
Output the fault relay action com-
mand.
 
◆
Level 2
 
◆
Display the fault code.
 
◆
Output the fault relay action com-
mand.
 
◆
Continue normal running of the ele-
vator.
 
◆
function is disabled.
 
◆
-
ing function is disabled.
Level 3
 
◆
Display the fault code.
 
◆
Output the fault relay action com-
mand.
 
◆
Stop output and apply the brake 
immediately after stop.
 
◆
elevator stops at special deceler-
ation rate, and cannot restart.
 
◆
elevator does not stop. In nor-
mal-speed running, the elevator 
stops, and then can start running 
at low speed after a delay of 3s.
Level 4
 
◆
Display the fault code.
 
◆
Output the fault relay action com-
mand.
 
◆
In distance control, the elevator 
decelerates to stop and cannot run 
again.
 
◆
elevator stops at special deceler-
ation rate, and cannot restart.
 
◆
elevator does not stop. In nor-
mal-speed running, the elevator 
stops, and then can start running 
at low speed after a delay of 3s.
 
◆
elevator does not stop. In nor-
mal-speed running, the elevator 
stops, and then can start running 
at low speed after a delay of 3s.
Level 5
 
◆
Display the fault code.
 
◆
Output the fault relay action com-
mand.
 
◆
The elevator stops immediately.
 
◆
elevator stops immediately and 
cannot restart.
 
◆
elevator does not stop. In nor-
mal-speed running, the elevator 
stops, and then can start running 
at low speed after a delay of 3s.