9 Description of Functions and Schemes 
- 
315
 -
3  Parameters
Function 
Code
Name Setting Range Default
F6-12  0 to F6-00 8
F6-59 Elevator function selection 1 Bit9: VIP function Bit9 = 1
F6-46 VIP function selection
Bit1: VIP enabled by terminal
Bit8: Number of VIP car calls limited
0
 
Example
1)  
Function 
Code
Name Setting Range Value Remarks
F6-00
elevator
F6-01 to 40 20
These two parameters are used to set 
elevator, determined by the number 
of actually installed leveling plates.
F6-01
the elevator
1 to F6-00 1
F6-12  0 to F6-00 8 Set the 8
th
FE-32
Elevator 
function 
selection 1
Bit9: VIP function Bit9 = 1 The VIP function is enabled.
F6-46
VIP function 
selection
Bit8: Number 
of VIP car calls 
limited
-
Bit8 = 1: The elevator responds to only 
one car call (the last one). Bit8 = 0: 
The number of car calls is not limited.
2)  Method of enabling VIP
to be set.
Function 
Code
Name Setting Range Value Remarks
F6-46
VIP function 
selection
Bit0: VIP enabled by 
Bit0 = 1
When there is a hall call at the VIP 
VIP enabled by terminal: The elevator enters the VIP state when the terminal for VIP 
hall call becomes ON. In this mode, when the terminal for VIP hall call becomes ON, 
passengers. F6-46 Bit0 needs to be set.
Function 
Code
Name Setting Range Value Remarks
FD-07
HCB: JP1 
input
NO input: 
1: Elevator lock signal 
2: Fire emergency signal
 
6: Door close button input
FD-07 = 4
1. These parameters are used to 
set the functions of JP1 and JP2 
on the HCB.
 3. You can use either of JP1 and 
JP2 for VIP input.
FD-08
HCB: JP2 
input
FD-08 = 4
F6-46
VIP 
function 
selection
Bit1: VIP enabled by 
terminal
Bit1 = 1
After the terminal for VIP hall 
call becomes ON, the system 
enters VIP running.