3.4. 4-eyes principle
Notes:
The 4-eyes principle can only be set with the master code.
This setting can only be made when the lock is open. After this function has
been programmed (activated), the lock can only be opened when two codes
are entered.
The programming or deletion of the 4-eyes principle is saved in the event log.
(For reading out the event log, see the manual of the PC software
CombiComm)
In addition to the master code, at least one user code must be programmed.
Activating the 4-eyes principle
*2*
Enter program number 2
123456 *
Enter the master code
1*
1
Activate the 4-eyes principle
Deleting the 4-eyes principle
*2*
Enter program number 2
123456 *
Enter the master code
0*
1
Delete the 4-eyes principle
Opening with the 4-eyes principle
1 010101
1
Enter the user number of the first code (e.g. 1) and
enter the first code (e.g. 010101)
1
Green LED is lit.
2 020202
1
Enter the user number of the second code (e.g. 2) and
enter the second code (e.g. 020202)