3.5. Setting the opening delay / release time
Notes:
• The opening delay can only be programmed by the master.
• The programming can only be done when the lock is open.
• The programming or deletion of the opening delay and release time is saved in
the event log. (For reading out the event log, see the manual of the PC
software CombiComm)
Setting the opening delay and release time
*3*
Enter the program number
123456 *
1
Enter the master code
01*
Set an opening delay, e.g. 01 min.
01*
1
Set a release time, e.g. 01 min.
The opening delay can be set in the range of 01 – 99 minutes.
The release time can be set in the range of 01 – 15 minutes. When 00 is entered, the
lock immediately opens after the opening delay has expired, without an additional
code entry or expiration of a release time.
Deleting the opening delay and release time
*3*
Enter the program number
123456 *
1
Enter the master code
00*
Delete the opening delay
00*
1
Delete the release time
Opening with opening delay and release time
1 010101
1
Enter the user number of the first code (e.g. 1) and
enter the first code (e.g. 010101)
(in the case of the 4-eyes principle, enter the second code
as well).
1
Expiration of the opening delay. The green LED flashes
every 5 seconds. After the time delay has expired, this is
signaled by the signal tone 15x. The green LED is lit. The
lock waits for the opening code to be entered again during
the release time.
1 010101
1
Enter the user number of the code (e.g. 1) and
enter the first code (e.g. 010101).
Lock opens. (Only one code is required, even with
the 4-eyes principle!)