Intel Desktop Board D2500CC Technical Product Specification
62
Figure 18. Fan Location Guide for Chassis Selection
(Chassis Orientation is Not Restricted)
For all chassis configurations, the heatsink performance parameter, Ψ
JA
should be less
than 3.85 °C/W. The detail thermal measurement metrology is described in the
TMSDG. For chassis that fail to meet the thermal specifications guideline highlighted
above, an actively cooled heatsink solution should be used.