Introduction
This manual contains specifications, operation instructions, and calibration instructions
for Intercomp's model CS1500 crane scale.
Specifications
Controls
General: Zero, lb/kg, Mode, Set, Print, Tare, On, Off
Display: 5 ½ digit LED or 5 digit LCD
Indicators: lb/kg, Gross/Net, Total/Peak
Electrical
Batteries: 8 X D-size disposable alkaline dry cells or rechargeable Nickel-
Cadmium cells.
Battery life: Up to 90 hours with alkaline batteries. Approximately 30 hours on a set
of fully charged Ni-Cad cells. (LED display)
Resolution: 20 bit A/D delivers over 1,000,000 internal counts.
Filtering: 6 Pole, 10 Hertz low pass.
Auto off: Low battery, or after adjustable time without use or motion.
Sleep mode: Display sleep mode after adjustable time without use or motion.
Auto-Zero: Satisfies all HB-44 requirements; selectable 0.6, 1, or 3 graduations.
Performance
Accuracy: ±0.1% of applied load or ± display graduation, whichever is greater.
Environmental
Humidity: 10 to 95% Non-Condensing
Temperature: Storage: -40 C to +75 C. / -40 F to +170 F.
Operating -10 C to +50 C. / +14 F to +122 F.