  • R
    Rebecca JordanAug 15, 2025
    Why Intercomp Scales show erratic or drifting weights?
    • S
      Stephanie ChapmanAug 16, 2025
      Erratic or drifting weights on Intercomp Scales can be caused by contamination on the circuit boards or a bad load cell. Inspect the scale for these issues. A rapid change in temperature may also trigger this symptom.
  • K
    Kimberly RodriguezAug 18, 2025
    What to do if Intercomp Scales will not power up and the display is blank?
    • J
      Jason LindseyAug 18, 2025
      If your Intercomp Scales won't power up and the display is blank, there are several potential causes. First, inspect the wiring harness for any damage. Next, measure the battery voltage and charge or repair as needed. You can also bridge the ON switch to see if the unit turns on. If none of these steps work, the circuitry may be defective, requiring replacement of the control panel. Also, unplug the load cell cable; if the scale then turns on, a load cell lead is shorted. Turn the power off and try each cell lead in turn to determine the source of the problem and inspect the cable.
  • J
    James JohnsonAug 21, 2025
    What to do if Intercomp Scales shows bad weights?
    • W
      wsmithAug 22, 2025
      If your Intercomp Scales are showing bad weights, check your weighing technique and the scale settings. Verify that your reference scale is correct and that the scale is spanned correctly. Also, inspect the interconnecting wiring and cables for any pinching or damage.
  • B
    Bruce RobertsonAug 25, 2025
    What to do if Intercomp CS750 Scales shuts off?
    • M
      Marcus HarrisonAug 25, 2025
      If your Intercomp Scales shut off, it could be due to low battery levels. Replace the batteries. If replacing the batteries doesn't solve the problem, it may be necessary to replace the control panel.
  • J
    Janice DavisAug 27, 2025
    What to do if Intercomp Scales show power up to random display?
    • R
      Rhonda PriceAug 28, 2025
      If your Intercomp Scales power up to a random display, test for low battery voltage and inspect for visible damage. If these steps don't resolve the issue, replace the control panel.
  • L
    Linda RosarioAug 30, 2025
    What to do if Intercomp CS750 low battery indicator will not turn-off?
    • A
      Angela HunterAug 30, 2025
      If the low battery indicator on your Intercomp Scales won't turn off, check the battery voltage level and replace the battery if required. If the battery voltage is correct, the control panel may need to be replaced.
  • J
    Jason CarterSep 2, 2025
    What to do if Intercomp Scales locks up?
    • B
      Brian KingSep 2, 2025
      If your Intercomp Scales locks up, it may be programmed incorrectly. This can be corrected by restoring the correct control parameters.
  • K
    karigonzalezSep 5, 2025
    Why Intercomp Scales have no response to one or more buttons?
    • D
      davidkennedySep 5, 2025
      If your Intercomp Scales are not responding to one or more buttons, the switch or the control panel may be defective. Check the programming of the scale; the zero button does not function while the scale is in motion.
  • M
    Michelle WilkinsSep 8, 2025
    How to fix slow operation of Intercomp CS750?
    • G
      georgecoffeySep 8, 2025
      Slow operation in Intercomp Scales can be due to a programmed change in the filter setting. This can be tuned by changing the "Average Rate" setting.
  • B
    brenda78Sep 12, 2025
    What to do if Intercomp Scales have no backlight?
    • S
      Sarah DavisSep 12, 2025
      If your Intercomp Scales have no backlight, it may be because the light sensor window is covered. If the light still doesn't turn on, replace the control panel.

Summary

Declaration of Conformity

Introduction

Specifications Overview

Details on controls, electrical, performance, environmental, and physical attributes of the scale.

Optional Radio

Information regarding the optional radio frequency features and requirements for the scale.

Weights and Measures

Optional Equipment

Details on optional accessories like serial output cables and thermal printers for the scale.

Operations

Operating Practices

Guidelines and warnings for the safe and correct operation of the crane scale.

Display and Controls

Overview of the scale's display and primary control buttons like ON/OFF and ACCUM/TOTAL.

Core Operation Modes

Explanation of essential operating modes: MODE, ZERO, Lb/Kg, and TARE functions.

IR Remote Control Features

Description of the functions and buttons available on the IR remote control.

Advanced Remote Functions

Details on using KEY TARE and PEAK functions via the IR remote.

Mode Menu Settings

Instructions for configuring various settings through the scale's Mode Menu.

Accumulation and Motion Detection

Information on accumulating totals and the scale's motion detection system.

Serial Output (Optional)

Scoreboard Connection

Details on connecting the scale output to a scoreboard or PC via serial port.

Maintenance

Calibration Menu

Overview of the calibration menu options and steps for initiating calibration.

Enabling Calibration Function

Procedure for accessing the calibration jumper to enable the calibration mode.

Setting Calibration Parameters

Detailed steps for setting various parameters before performing weight calibration.

Weight Calibration

Calibration Verification

Process for verifying the scale's calibration accuracy after adjustments.

Inspection Requirements

Periodic inspection requirements and frequency for the crane scale.

Service Categories and Types

Defines service categories and types of inspections needed for the scale.

Power;Batteries

Legal-for-Trade Sealing

Procedure for qualified facilities to apply legal-for-trade seals.

Troubleshooting

Problem Table

A table listing common symptoms, causes, and solutions for scale issues.

Error Messages

Explanation of various error messages displayed by the scale and their meanings.

Calibration Menu Skip SEEP

Reference for Cal Mode Numbers used with the 'SEEP' function in the calibration menu.

How to Contact Intercomp

Intercomp CS750 Specifications

General IconGeneral
BrandIntercomp
ModelCS750
CategoryScales
LanguageEnglish

Related product manuals