EasyManua.ls Logo

Intercomp CS750 - Introduction; Specifications Overview

Intercomp CS750
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS750 User Manual
Rev E, April 2018
Page 4 of 31
Introduction
This manual contains specifications, operating instructions and calibration procedures
for the Intercomp Model CS750 Crane Scale.
Specifications
Controls
General
Zero, lb/kg, Mode, Print, TARE, On, Off
Display
5 1/2 digit, 1 inch liquid crystal display (LCD) with automatic back
lighting.
Electrical
Batteries
4 X D-size alkaline
Battery Life
800 hours (1 month continuous use)
5000 hours in Stand-by mode. Using the backlight will reduce
battery life.
Filtering
Adjustable averaging up to 30 seconds.
Stand-by Mode
Scale goes into standby when shut off using the IR or RFX
remote or after an adjustable time without use or motion.
When in "stand-by" mode, scale can be turned on with the IR
or RFX remote.
Auto-Zero
Satisfies all HB-44 requirements.
Performance
Speed
4 display updates per second
Accuracy
0.1% of reading or 1 display graduation, whichever is
greater.
Calibration Interval
Twelve months recommended
Environmental
Humidity
10 to 95% Non-Condensing
Temperature
Operating: -28 C to +65 C. / -20 F to +150 F
Storage: - 40 C to +75 C. / - 40 F to +170 F
Ingress Protection
IP50
EMI/RFI
Meets Mil Spec 461
Physical
Dimensions
Control Box
4.25" x 5" x 8.5". / 10.8 cm X 12.7 cm x 21.6 cm
Lifting Eye to Hook (Standard)
12" / 30.5 cm
Weight
7.5 lb. / 3.4 kg