xGen Lite Installation and Programming Guide  41 
•  User Name must be entered with a space between the first and last name 
and with correct capitalization. 
•  If connected by Wired LAN, check the cable is plugged in and that the 
connection is working. 
•  Check Settings > Network > Enable UltraSync is ticked. 
•  Check that your mobile device has access to the internet (e.g. open a web 
browser). 
•  Check the UltraSync servers are correct under Advanced > UltraSync: 
- Ethernet Server 1 – xg1.ultraconnect.com:443 
- Ethernet Server 2 – xg1.zerowire.com:443 
- Wireless Server 1 – xg1w.ultraconnect.com:8081 
- Wireless Server 2 – xg1w.zerowire.com:8081 
•  Power cycle connected equipment including xGenLite and customer supplied 
router(s). 
Method 4: NXG-1820 Keypad 
The NXG-1820 is able to access all panel programming features with a valid 
installer code. 
1.  Press Menu, Installer PIN, ENTER, go to Program. 
2.  Scroll through the menus using the up and down buttons. Refer to Appendix 
3: Advanced Menu Tree on page 155. 
3.  Press an item to go down a level or to select an option. Press the back arrow 
to go up a level or to cancel without saving. 
4.  Repeatedly press the back arrow to return to the main menu. 
Note: NetworX keypads (including NX-1820) have limited access to xGenLite 
programming menus. xGenLite keypads (NXG-180 and touchscreen) are able to 
program legacy NetworX devices via the Advanced > Devices menu.