Chapter 2 — Installation Process
Vehicle Power Supply Installation Guide 17
Use Method B where the back side of the mounting location is
inaccessible. Note that this method requires that the mounting
plate be thick enough to accept and retain sufficient thread to
provide a secure and reliable mechanical installation.
To use mounting method A
1 Mark and center punch the two mounting hole locations.
2 Use a 1/4” drill bit to make the two mounting holes.
3 Use 1/4” hex bolts with flat washers and locking nuts to
install the power supply.
To use mounting method B:
1 Mark and center punch the two mounting hole locations.
2 Use a #7 drill bit to make the mounting holes.
3 Use a 1/4-20 tap to thread the mounting holes.
4 Place a lock washer on each bolt.
5 Insert the bolt/lock washer assemblies through the power
supply holes and into the threaded mounting holes.
Installing the Power Cables
Follow these guidelines and other instructions closely when
installing power cables.
Completely install power cables before making connections to
equipment.
Route the power cables from the general area where the power
supply will be mounted.
Use a snap-in bushing (requires a 9/16” hole) if the power
cable passes through a firewall or other sheet metal.
Make sure that cable routing does not interfere with other
equipment or vehicle controls.
Ensure that cable routing does not invite damage to the cable.
Never work on a powered (hot) system.