EasyManuals Logo

Intermec easycoder f2 Installation & Operation

Intermec easycoder f2
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Intermec EasyCoder F4 Installation & Operation IPL Version, Ed. 1 73
Appendix 2 Media Specifi cations
Setting the Media
Sensitivity
Number, cont.
The sensitivity number on each roll of thermal transfer media or
ribbon has an asterisk (*) in place of one of the digits. To optimize
the sensitivity number for thermal transfer media, you combine
the digits as in this example.
Media or Ribbon Sensitivity Rating Description
Thermal transfer media 56* The asterisk for the third digit
is reserved to identify the
ribbons sensitivity number.
Thermal transfer ribbon 5*7 The asterisk for the second
digit is reserved to identify the
medias sensitivity number.
567 Optimum sensitivity rating
To set the sensitivity rating for direct thermal media, use the
three-digit sensitivity rating located on the roll of media or listed
in the Direct Thermal Media Sensitivity Settings table, later in
this chapter.
To use DOS to set the media sensitivity number on a PC
1. At the DOS prompt, type the following command and press
Enter:
MODE COM1 96,E,7,1,N
2. Type the following command lines and press Enter:
COPY CON COM1
<STX><SI>g1,567<ETX>^Z
where:
<SI>g1,567 sets the media sensitivity number to 567.

Table of Contents

Other manuals for Intermec easycoder f2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec easycoder f2 and is the answer not in the manual?

Intermec easycoder f2 Specifications

General IconGeneral
BrandIntermec
Modeleasycoder f2
CategoryBarcode Reader
LanguageEnglish

Related product manuals