116 EasyCoder PX4i and PX6i Service Manual
Chapter 10 — Label Taken Sensor
10.3 Activating the LTS
In Fingerprint, the label taken sensor is enabled using the instruction
LTS& ON.
In IPL, the self-strip mode must be enabled. This can also be done by
executing the following commands:
<STX>R<ETX> (Enter print/confi guration mode)
<STX><SI>t1<ETX> (Enable self-strip)
10.4 Adjustment
The sensitivity of the Label Taken Sensor (LTS) may need to be adjusted
according to the ambient light conditions and the refl ective characteristics
of the back side of the media.
Fingerprint
The sensitivity can be adjusted in the Setup Mode (see Appendix A), or by
using setup fi les or setup strings (see Intermec Fingerprint v8.xx, Program-
mer’s Reference Manual). In the Setup Mode, the LTS setup options are
only displayed if an optional label taken sensor is installed in the printer.
• LTS Adjust:
Press <Enter>. A label is fed out. Remove the label and press <Enter>
again. A menu shows the sensitivity automatically selected by the fi rm-
ware and the range in which the LTS will work. Press <Enter> again and
you will proceed to the LTS Test menu.
• LTS Test:
Press <Enter>. A label is fed out. Remove the label and a new label
should be fed out automatically. Repeat until you are sure the LTS
works properly. Then press <Enter> to stop and exit.
• LTS Value:
Press <Enter>. You can enter a new value in the range indicated in the
LTS Adjust menu (see above). Min/max values are in the range 0-10.
IPL
The sensitivity can be adjusted in the Setup Mode (see Appendix A).
In the Setup Mode, select the Confi guration option.
Select LTS Calibration and press the T key.
• Press <Enter>
A number of labels are fed out. Remove the labels and press <Enter>.
The sensor has now been automatically adjusted and the resulting
sensitivity is displayed as a numeric value in the range of 8 to 14.

Table of Contents

Other manuals for Intermec EasyCoder PX4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PX4i and is the answer not in the manual?

Intermec EasyCoder PX4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution300 x 300 DPI
DisplayLCD
Product colorSilver
Keyboard layoutNumeric
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.4/10 mm
Maximum label width120 mm
Maximum label length2.7 m
Maximum roll diameter213 mm
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)20 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth482 mm
Width238 mm
Height275 mm
Weight12850 g