EasyCoder PX4i and PX6 Service Manual 221
Chapter 17 — Troubleshooting
Description:
No messages appear in the display window after power-up.
Power LED is lit.
Green background lighting in display window is lit.
Possible Causes and Suggested Remedies:
Display not utilized by custom-made program (Fingerprint only).
- If there is no display function in the Test Mode, the display is out of
order and the console unit needs to be replaced. Else, check out the
custom-made program.

Table of Contents

Other manuals for Intermec EasyCoder PX4i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder PX4i and is the answer not in the manual?

Intermec EasyCoder PX4i Specifications

General IconGeneral
Print technologyDirect thermal
Maximum resolution300 x 300 DPI
DisplayLCD
Product colorSilver
Keyboard layoutNumeric
Standard interfacesRS-232, USB 2.0
Internal memory16 MB
Media thickness2.4/10 mm
Maximum label width120 mm
Maximum label length2.7 m
Maximum roll diameter213 mm
Supported network protocolsTCP/IP, LPR/LPD, FTP, BOOTP, DHCP, HTTP, SNMPv3, SMTP, SNMP-MIB II
Power requirements90 - 265 VAC, 45 - 65Hz
Power consumption (standby)20 W
Power consumption (printing)125 W
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)40 - 104 °F
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth482 mm
Width238 mm
Height275 mm
Weight12850 g