Chapter 2 — Installing the Forklift Power Supply
PB50 and PW50 Forklift Power Supply Installation Guide 21
Connecting to Top-Mount Battery Terminals
Perform the following procedure to attach the forklift battery
cable to a top-mount battery terminal.
To connect the forklift battery cable to a top-mount battery terminal
1 Disconnect the negative battery cable, and then disconnect
the positive battery cable.
2 Remove the bolts from the forklift battery terminals.
3 Replace those bolts with 3/8-inch x 1-1/2-inch bolts and nuts
from the installation kit. Tighten the nuts.
4 Reinstall the positive battery cable, and then tighten the nut
securely.
5 Slip a 3/8-inch washer onto the extended end of each bolt.
6 Slide the positive (fuse link with red wire) terminal ring from
the input power cable onto the positive (+) battery bolt.
7 Slip a second 3/8-inch washer onto the bolt.
8 Thread and tighten a second 3/8-inch nut onto the bolt.
3/8” nut
3/8 x 1-1/2” bolt
Forklift battery
Forklift battery cable
Fuse holder
3/8” washers
Connecting the Forklift Battery Cable to a Side-Mount Battery Terminal