ZSim v5.XX User‘s Guide 5
ensure a secure update. Verify that the update has been carried out by
printing a configuration label.
Note: e default instruction prefix “^” and the default
delimiter “,” are used in the samples at the end of the section.
[ParamName] ParamNo ParamValue Default Comment
Label length 1 Calibrated N/A
Y-Offset 2 0 +/-999 dots
X-Offset 3 0 +/-999 dots
Sim resolution 4 sysvar(21) 6,8 or 12
Label width 5 sysvar(22) Depends on head
Print Mode 6 T(Tear-off) T, P, R, C
Start Adjust 7 Depends on model
Stop Adjust 8 Depends on model
Peel Off 9 Depends on model
Cut Off 10 Depends on model
Feed action at
power up
11 1 0=no action, 1=feed,
2=calibrate
Feed action at
head down
12 1 0=no action, 1=feed,
2=calibrate
In Port 13 auto net1:, uart1:, parallel
Default Media
Darkness
14 15 1-30
Optimize Barcode
Size
15 0 0-9
LTS-sensor 16 1/0 auto 1=ON 0=OFF
Optimize Image
Mag.
17 1/0 1 1=ON 0=OFF
Allow Reverse
print
18 1/0 1 1=ON 0=OFF
Permanent Save 19 1/0 0 1=ON 0=OFF
Format Instruc-
tion Prefix
20 ^ Any ASCII char.