(133IO) SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 04/10/2022
133
A
SAVE THESE INSTRUCTIONS
English
Page 12
Set BOOST operating hours:
1.
Press button to unlock the keypad. With LED flashing, press
button to set the desired operating hours. Total of 4 settings: 36 hours,
48 hours, 60 hours and 00 (OFF). Keep pressing button to repeat
the cycle.
2.
With the desired hour value showing, press button to lock the
keypad controls. The BOOST indicator will light up when activated.
The system is now starting more sodium hypochlorite sanitizer production. After the boost
procedure has been completed, the system will automatically switch to the normal working
mode. The LED display will show the remaining BOOST hours first until it’s finished and
then the remaining programmed saltwater system hours.
NOTE:
If you forget to lock the keypad controls, the system will automatically lock it and
start working 10 seconds later. During the BOOST mode, periodically test the free chlorine
level which should not exceed the recommended level of 3.0 parts per million (ppm). Do
not use the pool if the free chlorine level exceeds 5.0 ppm.
3.
To cancel the boost cycle, press
button to unlock the keypad, then press button
and reset the hour to “00”.
Set electrode Self-Clean cycle time:
The default self-clean cycle time is 14 hours. To adjust the self-clean
cycle time:
1.
Press
button to unlock the keypad and the LED display is
flashing. Depending on your pool water calcium hardness level,
press
button to select the self-clean cycle time as below. Total
of 3 settings: 14 hours, 10 hours and 06 hours.
NOTE:
The life of the cell varies depending on water conditions, pool usage and
operating time of the device. Select 14 hours cycle time to maximize the life of the
electrolytic cell if the calcium hardness level is up to 150 ppm. Manual routine cleaning
and maintenance will further lengthen the life of the electrolytic cell.
2.
With the desired self-clean hours showing, press
button to lock the keypad controls
and the LED display will return to the normal operating time. The system will reverse the
polarity of the electrode
(7)
every time according to the selected hours.
NOTE:
If you forget to lock the keypad controls, the system will automatically lock it and
start working 10 seconds later.
OPERATION INSTRUCTIONS (continued)
Calcium Hardness Self-clean cycle time
0 - 150 ppm Reverse polarity every 14 hours
150 - 250 ppm Reverse polarity every 10 hours
250 - 350 ppm Reverse polarity every 06 hours