44
FLASH
CODE
FAULT EFFECT Comments
7
Error in Shark
remote
Stops driving
Check remote bus cable and all
connecting plugs.
Replace remote.
8
Error in Shark
power module
Stops driving
Check all cables and connecting plugs in
the Shark system.
Replace power module
9
Communication
error in Shark
system
Stops driving
Check all cables and connecting plugs in
the Shark system.
Replace remote.
10
Unknown error Varying
Check all cables and connecting plugs.
Talk to your dealer.
11
Incompatible
remote
Stops driving
The wrong remote type is connected.
Ensure that the power module type code
matches the remote type code.