Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety
protection features may activate and cause the unit to disable.
COOL mode HEAT mode DRY mode
Room Temperature
17°C - 32°C
(62°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 24°C
(5°F - 75°F)
0°C - 50°C
(32°F - 122°F)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air lters.
FOR OUTDOOR UNITS
WITH BASEPAN HEATER
OR CRANKCASE HEATER
Inverter Split Type
When outside temperature
is below 0°C(32°F ), we
strongly recommend
keeping the unit plugged
in at all time to ensure
smooth ongoing
performance.
NOTE: Room relative humidity less than 80%. If the air conditioner operates in excess of this
gure, the surface of the air conditioner may attract condensation. Please sets the vertical air
ow louver to its maximum angle (vertically to the oor), and set HIGH fan mode.
Page 10
Other Features
Auto-Restart
If the unit loses power, it will automatically
restart with the prior settings once power has
been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO
(COOL), or DRY modes, the air conditioner will
continue operate at very low power to dry up
condensed water and prevent mildew growth.
Louver Angle Memory
When turning on your unit, the louver will
automatically resume its former angle.
Refrigerant Leakage Detection
ECO Intelligent eye
The SLEEP function is used to decrease
energy use while you sleep (and don’t
need the same temperature settings to
stay comfortable). This function can only
be activated via remote control. And the
Sleep function is not available in FAN or
DRY mode.
When in COOL mode, the unit will increase
the temperature by 1°C (2°F) after 1 hour,
and will increase an additional 1°C (2°F) after
another hour.
When in HEAT mode, the unit will decrease
the temperature by 1°C (2°F) after 1 hour,
and will decrease an additional 1°C (2°F)
after another hour.
Sleep Operation
Wireless Control
Wireless control allows you to control your air
conditioner using your mobile phone and a
wireless connection.
For the USB device access, replacement,
maintenance operations must be carried
out by professional staff.
Set
temperature
1hr
1hr
Keep
running
SLEEP Operation
Saving energy during sleep
Heat mode( -1 C/2 F)
Cool mode(+1 C/2 F)
A guide on using the infrared remote is not
included in this literature package.
Not all
the functions are available for the air
conditioner, please check the indoor display
and remote control of the unit you purchased.
The sleep feature will stop after 8 hours and
the system will keep running with nal situation.
Active Clean function (some units)
-- The Active Clean Technology washes away
dust, mold, and grease that may cause odors
when it adheres to the heat exchanger by
automatically freezing and then rapidly thawing
the frost. A “pi-pi” sound will be heard.
The Active clean operation is used to produce
more condensed water to improve the cleaning
effect, and the cold air will blow out. After
cleaning, the internal wind wheel then keeps
operating with hot air to blow-dry the evaporator,
thus preventing the growth of mold and keeping
the inside clean.
-- When this function is turned on, the indoor
unit display window appears “CL ” , after 20
to 45 minutes, the unit will turn off automatically
and cancel Active Clean function.
Breeze Away
This feature avoids direct air ow blowing on
the body and make you feel indulging in
silky coolness.
The indoor unit will automatically display “EL0C”
when it detects refrigerant leakage.
The system is controlled intelligently under
Intelligent eye mode. It can detect the people’s
activities in the room. In cooling mode, when you
are away for 30 minutes, the unit will automatically
lower the frequency to save energy(for Inverter
models only). And the unit will automatically start
and resume operation if sensing human activity
again.

Table of Contents

Other manuals for INVENTOR LDVI-09WFI/LDVO-09

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVENTOR LDVI-09WFI/LDVO-09 and is the answer not in the manual?

INVENTOR LDVI-09WFI/LDVO-09 Specifications

General IconGeneral
BrandINVENTOR
ModelLDVI-09WFI/LDVO-09
CategoryAir Conditioner
LanguageEnglish

Related product manuals