Setting Setting
WORK MODE
Select the peak clipping and valley filling mode, you also need to set
the charge and discharge time.
Time setup
Interface
Description
CHAG S T AR T :
00
:00
This interface is used to opt for the time
of peak load shifting.
Press Up/Down button to move
the corresponding options.
Press Enter to enter the selected menu.
Press Esc button to return to the working
mode interface.
C H A R G E END:
00
:00
DISC S T A R T :
00
:00
DISCHA END:
00
:00
PV INPUT
Interface
Description
--INPUT MODE--
1: IN DE PEN DAN T
2: P A R A L L E L
3: CV
Setup of PV Input mode.
The factory setting by default is
Independant, When parallel input is set
to be stand-alone
mode, PV power will be imbalanced.
Interface
Description
--WORK MODE--
1 : SELF COMSUME
2: P EAK SH I FT
3:BAT P RI ORITY
This interface is used to select
the working
mode.
Press ESC button return to setting
interface.
( refer to 8.2.1)
EPS ENABLE
Interface Description
-- EPS ENABLE --
1:DI SABLE
2:ENABLE
When the Grid PV is powered o, Enable the
battery to supply power to the load, default
option is enable.
REMOTE CTRL
Interface Description
--REMOTE CTRL--
1:DISABLE
2:ENABLE
When you want to remotely control the
machine, you need to enable it.
Default option is disabled.
Battery wake up enable
Interface Description
-- BAT WAKE-UP --
1:DI SABLE
2:ENABLE
Battery wake-up enable
setting. The default option
is disabled.
START DELAY
Interface Description
--START-UP DELAY--
INPUT:60
UINT:SEC
The input value ranges from 20 to
300,which varies with dierent
standards.
50 51