Goodrive350-19 series VFD Troubleshooting
- 401 -
The brake force is
insufficient.
The encoder is abnormal.
The zero servo detection
parameter is set is
improperly.
Check whether the brake
works normally.
Check whether the encoder
works normally.
Check whether the zero servo
tolerance pulse threshold is
too small.
The brake feedback circuit
is disconnected or in poor
contact.
The brake feedback
detection time is too short.
Check the brake feedback
circuit.
Increase the detection time
P90.32 to a proper value.
Loose rope
protection alarm
The hook rope is abnormal.
The downward loose rope
parameter setting is
improper.
Check whether the hook rope
is normal.
Check whether the downward
loose rope detection torque is
proper.
PT100
overtemperature
alarm
The current environment
temperature is too high.
PT100 overtemperature
protection setting is
improper.
Check the current
environment temperature.
Check whether PT100
overtemperature protection
point is too small.
PT1000
overtemperature
alarm
The current environment
temperature is too high.
PT1000 overtemperature
alarm setting is improper.
Check the current
environment temperature.
Check whether PT1000
overtemperature protection
point is too small.
PT100
disconnection alarm
PT100 connection circuit is
opened.
Check PT100 connection
circuit.
PT1000
disconnection alarm
PT1000 connection circuit
is opened.
Check PT1000 connection
circuit.
PTC
overtemperature
alarm
The current environment
temperature is too high.
Check the current
environment temperature.
Note: After fault recovery, the corresponding alarm is automatically reset.