iMars grid-tied solar inverters Safety precautions
8
Keep the installation site away from children and other public places.
Remove the metal jewelry such as ring and bracelet before installation and
electrical connection to avoid electric shock.
Do cover solar modules with light-tight materials. Exposed to sunlight, solar
modules will output dangerous voltage.
The inverter input voltage does not exceed the maximum input voltage;
otherwise inverter damage may occur.
The positive and negative pole of solar modules can not be grounded, otherwise
irrecoverable damage may occur.
Ensure the proper grounding of the inverter, otherwise, improper connection or
no grounding may cause stop of the inverter.
Ensure reliable installation and electrical connection.
Note: iMars grid-tied solar inverters are only for crystalline silicon solar modules.
1.2.2 Grid-tied operation
Only qualified electricians are allowed to operate the inverter under the
permission of local power departments.
All electrical connections must meet the electrical standards of the
countries/regions in which the project is located.
Ensure reliable installation and electrical connection before operation.
Do not open the cover of inverter during operation or voltage is present.
1.2.3 Maintenance and inspection
Only qualified electricians are allowed to perform the maintenance, inspection,
and components replacement of the inverter.
Contact with the local dealer or supplier for maintenance.
In order to avoid irrelevant personnel from entering the maintenance area during
maintenance, temporary warning labels must be placed to warn
non-professionals to enter or use fence for isolation.
Firstly disconnect all power supplies of the grid to the inverter before any
maintenance, and then disconnect the breakers and wait for at least 5 minutes
until the inverter is discharged before maintenance.