SPC Series Solar Pump Inverter Function parameter list
-34-
P08 group Enhanced functions
Function
code
Name
Description
Default
Modify
P08.28
Auto fault reset
count
Setting range: 010
The following faults can be automatically
reset:
OC1: Overcurrent during acceleration
OC2: Overcurrent during deceleration
OC3: Overcurrent during constant speed
running
OV1: Overvoltage during acceleration
OV2: Overvoltage during deceleration
OV3: Overvoltage during constant speed
running
UV: Bus undervoltage fault
OL1: Motor overload
OL2: Inverter overload
SPO: Phase loss on output side
EF: External fault
CE: RS485 communication fault
ItE: Current detection fault
tE: Motor autotuning fault
EEP: EEPROM operation error
END: Running time reached
OL3: Electronic overload
ETH1: To-ground short-circuit fault 1
ETH2: To-ground short-circuit fault 2
dEu: Speed deviation fault
STo: Mal-adjustment fault
LL: Underload fault
5
P08.29
Auto fault reset
interval
0.13600.0s
10.0s