SPC Series Solar Pump Inverter Function parameter list
-37-
Function
code
Name
Description
Default
Modify
0: Act during the automatic reset period
1: Do not act during the automatic reset
period
P11.14
Speed
deviation
detection value
0.050.0%
10.0%
P11.15
Speed
deviation
detection time
0.010.0s (No speed deviation protection
for the value=0.0)
0.5s
P13 group SM control
Function
code
Name
Description
Default
Modify
P13.00
SM
injected-current
decrease ratio
0.0%100.0% (of the motor rated
current)
80.0%
P13.01
Initial pole
detection
method
0: Source current
1: High frequency superimposition
(reserved)
2: Pulse superimposition (reserved)
0
P13.02
Injected current
1
-100.0%100.0% (of the motor rated
current)
20.0%
P13.03
Injected current
2
-100.0%100.0% (of the motor rated
current)
20.0%
P13.04
Source-current
switchover
frequency
0.00HzP00.03 (Max. output frequency)
10.00Hz
P13.06
High frequency
superimposed
voltage
0.0300.0% (of the motor rated voltage)
100.0%
P13.11
Mal-adjustment
detection time
0.010.0s
0.5s
P13.12
SM
high-frequency
compensation
coefficient
0.0100.0%
0.0