4. Functioning principles
4.4.2 Safety working modes
Via the Inxpect Safety application, you can select which safety working mode each sensor will employ for each of
its detection fields:
l Both (default):
o
the sensor performs the access detection function when it is in normal operation (No alarm status)
o
the sensor performs the restart prevention function when it is in alarm status (Alarm status)
l Always access detection:
o
the sensor always performs the access detection function (No alarm status + Alarm status)
l Always restart prevention:
o
the sensor always performs the restart prevention function (No alarm status + Alarm status)
Inside the field of view of each sensor you can set up to two detection fields:
l Detection field 1, e.g. used as alarm area
l Detection field 2, e.g. used as warning area