[P14] Vapor Temperature Compensation
The sound velocity in air increases or decreases at a uniform rate of 60cm/
o
C,
however in atmospheres other than air it will change at a dierent rate. This
option allows the rate of change in cm/
o
C to be set according to the present
atmosphere and temperature. The level indicated, ould be compared with
the actual level, several times, then Vapor Temperature Compensation
adjusted accordingly, to obtain an accurately displayed reading. The pre-set is
60cm/
o
C.
[P15] Detection Algorithm
This option determines the detection algorithm. The returned signal can be
strong or weak according to eld condition. This option chooses what signal
is eective.
Option Description
1
Automatic
2 Effective only for the First signal
[P16] Detection Target
The signals reectance is subject to change by the measuring target.
Option Description
1
Liquid
2
Bubble Liquid
3
Solid
4
Powder