18
USE AND MAINTENANCE MANUAL
EN
428000467237 MILLENNIUM
9. MAINTENANCE
The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table
below, contacting the authorised Technical After-sales assistance when indicated.
OPERATION FREQUENCY
ORDINARY
EXTRAORDINARY
PERSONNEL
AUTHORISED
Depending on the
Use and Necessity
Monthly
Every 6 months
Annual
CLEANING THE EXTERNAL SURFACES
X X
USER
CLEANING THE ACCESSIBLE INTERNAL PARTS
(without the use of tools)
X X
CONTROL POWER SUPPLY CABLE,
PLUGS AND / OR ELECTRICAL SOCKETS
X X
INTEGRITY CONTROL SEAL
X X
FILTER CLEANING CONDENSING UNIT
(whenever present)
X X
CLEANING THE DEFROSTING WATER COLLECTION TRAY
X X
TECHNICAL
ASSISTANCE
CONDENSER CLEANING
X X X
CHECK COMPRESSOR OIL LEVEL
(whenever present)
X
AIR TANK DRAINING
(whenever present)
X X
CONTROL PNEUMATIC CONNECTIONS
(whenever present)
X X
INTEGRITY CONTROL PIPE COOLING SYSTEM
X X
INSPECTION OF CABLES
INTERNAL CONNECTIONS AND POWER
X X
CLEANING CONDENSATE DRYING SPONGES
(whenever present)
X X
LAMP / LED REPLACEMENT
(whenever present)
X
CONTROL PANEL REPLACING
(electronic control unit - thermostat - etc.)
X
REPLACEMENT POWER SUPPLY CABLE, PLUGS AND / OR ELECTRICAL SOCKETS
X
ATTENTION
After all maintenance it is mandatory to perform all electrical safety tests in accordance with
the IEC EN 50106 Standard.