9 Faults
net input plug not connected
check net input cable
connection
main switch not switched on
remove net input plug,
renew fuse
power supply voltage
cannot switch on by
POWER button
hood / door is not closed
Emergency stop switch is
unlocked
unlock Emergency stop
switch
software works not
correctly
main switch not switched on
power supply for the power
amplifiers not switched on
power amplifiers by
pressing POWER-button
motor cables not connected
no communication via
serial interface
incorrect COM port selected
milling spindle is not
working
incorrect setting in the
spindle module DLL
(only DNC mode)
check settings and change
if applicable
switch on the milling spindle
(only 100-230 V) is switched
OFF
moving distances of the
axles is incorrect
spindle pitch is not correct in
the software Remote
(in DNC mode)
change spindle pitch in
software Remote/6/
spindle pitch is not correct
set in the initialize section of
user program or in the
programming software
PALPC (in CNC-mode)
change spindle pitch in the
user program or
programming software