ENGINE FUEL 6C–11
3. Install the nut (1) to the dial gauge holder (2).
Nut: 157892-1000 (ZEXEL)
4. Install the pin to the dial gauge.
Note: Pin lengths of the pins do not include the threaded
portions.
Pin (l=60 mm): 157892-5300 (ZEXEL)
Dial gauge: 157892-3800 (ZEXEL)
5. Secure the dial gauge to the nozzle holder using the
nut so that the pin contacts the tip of the first spring
seat.
CAUTION:
• Secure the dial gauge so that a stroke of 2
mm can be measured.
• Do not over-tighten the nut as the dial gauge
shaft may jam. Confirm from the dial gauge
that the shaft moves smoothly.
Legend
(1) 1st spring seat
(2) Nozzle holder
(3) Pin
(4) Holder
(5) Nut
(6) Dial gauge