Overrunning clutch shaft return
Press against the head of the overrunning clutch with
your hand.
Measure the movement (return) of the clutch shaft.
If the return is outside the specified range, adjust the
packing between the front bracket and the magnetic
switch.
If adjustment is not possible. Replace the lever.
Performance test
1. Connect the starter motor as shown in the
illustration.
Legend
(1) Battery
(2) Ammeter
(3) Voltmeter
2. Turn the switch on.
3. Measure the starter motor speed, the current, and
the voltage.
If the starter motor speed is less than the specified
value, the starter motor requires further servicing.
Starter motor minimum speed: 3,300 min
-1
(No
load)
If the measured starter motor minimum current
and/or terminal voltage is different from the specified
value, the starter motor requires further servicing.
Starter motor minimum current: 85 A (No load)
Starter motor terminal voltage: 23 V (No load)