Load Function
The procedures to set Von function are as follows.
1. Press the composite keys [Shift]+[V-set] (Config) on the front panel to enter
the configuration menu.
2. Use knob or Up/Down key to select Von and press [Enter].
3. Use knob or left/right key to select the desired Von mode.
Latch mode
Living mode
4. Use number keys or knob to set Level and press [Enter].
5.2 Advanced Feature
5.2.1 LIST Function
The IT6000B series power system supports a total of 10 List files (List01 to
List10), each of which can be set up to 200 steps. You need to edit the voltage/
current value, slope and time width of each step, or you can set repeat times (1
to 65535) for each List file. After the file is edited completely, you can trigger the
selected List file to run according to the selected trigger mode.
The descriptions of list function menu are listed in the table below.