Technical Specification
Parameter IT6015B-80-450
Power factor ≥0.99
Islanding protection Active islanding protection
Setup stability-
30min (of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Setup stability-8h
(of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Readback stability-
30min (of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Readback stability-
8h (of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Input impedance
quiescent current
<10mA at Vmax
Efficiency
90%
Remote Sense
Compensation
Voltage
≤5V
Command Re-
sponse Time
2ms
Storage
Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, UVP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP,
optional: GPIB, RS232
Isolation (input to
ground)
500V
Working
Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
*1. The instrument needs to be customized under other AC input voltage
ranges. For models equipped with an emergency stop module (including AC
contactor), the AC input voltage range can only be: 342V528V.