Technical Specification
Parameter IT6006B-800-25
Note: 1. The instrument needs to be customized under other AC input voltage ranges. For mod-
els equipped with an emergency stop module (including AC contactor), the AC input voltage
range can only be: 342V528V
Load Mode:
Parameter IT6006B-800-25
Rated value ( 0
-50 )
Input voltage
0800V
Input current
025A
Input power
06kW
Input resistance
0.0017500Ω
Min. operating
voltage
2.1V at 25A
Setup Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Resistance 0.001Ω
Read Back
Resolution
Voltage
0.01V
Current 0.001A
Power 0.001kW
Resistance 0.001Ω
Setup Accuracy
(within 12 months,
25 ±5) ±(
ofOutput+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Read Back Accu-
racy (within 12
months, 25 ±5)
±(of Output
+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Setup Temperature
Coefficient ±(of
Output/+Offset)
Voltage
≤50PPM/
Current ≤200PPM/
Read Back Temper-
ature Coefficient
±(of Output/
+Offset)
Voltage
≤50PPM/
Current ≤200PPM/
Dynamic Rising slope
25A/ms