Technical Specification
Parameter IT6018B-1500-40
Fall Time( full load ) Voltage
≤15ms
Transient Response Time Voltage
≤2ms
AC Input
Voltage (Three-
phase four-wire) 1
198V264V (Derating 50%) 342V528V
Maximum Input
Current
33.37A
Maximum Input Ap-
parent Power
19.8kVA
Frequency
47Hz63Hz
Setup Stability-30min Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Setup stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback Stability-30min Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Readback stability-8h Voltage
≤0.02% + 0.02%FS
±(of Output+Offset)
Current ≤0.1% + 0.1%FS
Efficiency
92%
Remote Sense Compensa-
tion Voltage
≤15V
Command Response Time
2mS
Power Factor 0.99
Storage Temperature
-10℃~70
Protective Function
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard Interface
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
Isolation ( output to ground)
1800V
Working Temperature
050
Dimension ( mm) 483mm(W)*801.61mm(D)*151.3mm(H)
Weight( net)
40KG
Note: 1. The instrument needs to be customized under other AC input voltage ranges. For mod-
els equipped with an emergency stop module (including AC contactor), the AC input voltage
range can only be: 342V528V
Load Mode: