EasyManua.ls Logo

ITech IT6952A - Status:questionable:enable <Enabled Value; System:version

ITech IT6952A
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Commands
Copyright ©ITECH Electronic Co., Ltd. 16
STATus:QUEStionable:ENABle <enabled value>
This order can set the parameter of quest event enable register. The power
supply will return a decimal number which is the
binary-weighted sum of the
enable register.
Order syntax:
STATus:QUEStionable:ENABle <NRf>
Parameter:
0 to 65535
Reset value:
Consult *PSC order
Example:
STATus:QUEStionable:ENABle 16
Quest syntax:
STATus:QUEStionable:ENABle?
Return parameter:
<NR1>
Reference order:
*PSC
SYSTem:VERSion?
This order can query the version of the SCPI order. Returned value is a string
like “YYYY.V”, In which the YYYY is the year of this version, V is the version.
Order syntax:
SYST:VERS?
Parameter:
None
Return parameter:
<NR2>
Example:
1.00, 1991.1
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT6952A

Related product manuals