Current Control Commands
Copyright ©ITECH Electronic Co., Ltd. 27
Return parameters:
<NR2>
[SOURce:]CURRent:PROTection[:LEVel]
This command is used to set the upper limit current value of the overcurrent
protection OCP. If the peak value of the output current is higher than the OCP
upper limit, the output of the power supply will turn off and an alarm tone will be
generated. After the overcurrent protection status occurs, the command
CURR:PROT:CLE can be sent to clear the overcurrent protection status.
Order syntax:
[SOURce:]CURRent:PROTection[:LEVel]
Parameters:
MIN to MAX
Unit:
A
Query syntax:
[SOURce:]CURRent:PROTection[:LEVel]?
Return parameters:
<NR2>
[SOURce:]CURRent:PROTection:STATe
This command is used to enable or disable the OCP function, that is, set the
overcurrent protection status.
Order syntax:
[SOURce:]CURRent:PROTection:STATe
Parameters:
0|1|OFF|ON
Query syntax:
[SOURce:]CURRent:PROTection:STATe?
Return parameters:
0|1
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com

Table of Contents

Other manuals for ITech IT6952A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6952A and is the answer not in the manual?

ITech IT6952A Specifications

General IconGeneral
BrandITech
ModelIT6952A
CategoryPower Supply
LanguageEnglish

Related product manuals