Note: Itron recommends that users only enable the configurations used by your business
unit. Having only one meter configuration option enabled (with the endpoint variable being
checked in the FDM business unit) eliminates the need to enter the number of dials.
Field Collection System (FCS) (Mobile Mode only)
In FCS, a Read Type Code can be assigned to a meter session. The Read Type Code in
conjunction with the Endpoint Type is used to determine how the endpoint reading is
formatted using the Endpoint Translation table in FCS. The Endpoint Translation table is a
configurable table that is used to determine the truncation factor and multiplier for each
reading. A default Endpoint Translation is defined for each type of endpoint supported by
FCS (ReadType of 00 for each EndpointType). If the default Endpoint Translation is not
formatting the read correctly, an additional Endpoint Translation can be defined to properly
format the read.
Since the Endpoint Translation Code is based on the Read Type Code and the Endpoint
Type, changing from a 40-series endpoint to a 100-series endpoint can cause the reading to
be truncated differently. If you are having issues with your reading after a change out, check
your Read Type Codes and Endpoint Translation Codes.
OpenWay Operation Center (OWOC)
The OpenWay Operation Center (OWOC) collects the raw reading and passes it on without
making any formatting changes.
Itron Enterprise Edition (IEE) Meter Data Management
The standard unit of measure (UOM) in IEE is cubic feet for gas endpoints. The reading
passed on by the gas endpoint is not in cubic feet if endpoints with 6 and 7-dial meter
configurations are programmed, so adjustments are required to set the correct unit of
measure. If you are having issues with your readings in IEE but your endpoint and meter
index match, check your unit of measure within IEE.
100G Series Remote Module Programming
100G Series Gas ERT Module Installation Guide, Remote Mount TDC-0824-017 17
Proprietary and Confidential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON 100G DLS Datalogging and is the answer not in the manual?

ITRON 100G DLS Datalogging Specifications

General IconGeneral
BrandITRON
Model100G DLS Datalogging
CategoryControl Unit
LanguageEnglish

Related product manuals