Installing the 100W/100W+ and 100WP/100WP+ ERT Module
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 21
Proprietary and Confidential
Caution Do not over-tighten the mounting screws. Over-tightening the mounting screws may break the
ERT module mounting tabs.
Shelf Mount Installation
This section describes 100W/100W+ and 100WP/100WP+ ERT module installation using a shelf mount
adapter to mount the ERT module in a pit lid slot.
Caution Observe the following guidelines for mounting the ERT module using the shelf
mount procedure:
• ERT module positioning other than upright could negatively affect radio
performance and battery life.
• Use only Itron-approved splice kits or inline connectors.
The pit lid and slot must have the correct dimensions for the ERT module assembly to fit
properly.