6. The top of the rod must be 3-1/2 inches below the bottom of the lid. Place the Riva module
on the rod. Completely insert the rod into the pit module's rod mount hole. Do not force the
pit module onto the rod. If the pit module does not slide freely on the rod, remove the pit
module and examine the pit module rod hole and rod for burrs or obstructions.
7. You may secure the pit module to the rod with a self-drilling screw through the hole in the top
of the pit module's rod mount cavity.
8. Connect the register (black connector, 1), optional remote antenna (red connector, 2) and
optional telemetry device (blue connector, 3) into the appropriate connection.
9. Turn the connector locking ring to secure the connection.
Caution: Turn only the locking ring. Turning the entire connector could damage
the connector pins.
10. Installation is complete when the pit module is perpendicular to the underside of the lid. The
pit module must not contact the pit structure or lid.
Caution: Verify that the pit lid does not touch the pit module when the lid is
replaced. There must be a 1 to 2-inch space between the top of the pit module and
the bottom of the pit lid. If the pit module is installed too high or too low, or is
touching any of the surrounding surfaces, adjust the installation as necessary.
08 January 2020 815-0006-01 Itron, Inc. Page 29 of 48
Template 4 Installing the OpenWay Riva 500W ERT Pit Module

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITRON ERW-1601-001 and is the answer not in the manual?

ITRON ERW-1601-001 Specifications

General IconGeneral
BrandITRON
ModelERW-1601-001
CategoryControl Unit
LanguageEnglish

Related product manuals