5
Using the Itron Cable Armor
This section describes the procedure for installing Itron cable armor in a field installation. The
Itron cable armor provides a layer or protection for the module's cable jacket. Itron cable armor is
available in five-foot sections.
Warning
Use caution when you are installing the cable armor.
Itron cable armor is stainless steel and may have sharp edges.
If you remove the inline connector from the pit module to install the cable armor, you must
use an Itron handheld to reprogram the pit module using FDM Endpoint Tools.
Perform a Check Endpoint function (with FDM Endpoint Tools) after you reprogram the pit
module to verify communication with the meter register.
Installing
1. Remove the pit module from the pit.
Note: If it is possible in your field installation, keep the pit module connected to the
register.
2. Cut a two to three inch strip of electrical tape.
3.
Wrap the entire piece of electrical tape around the pit module cable near the inline
connector.
08 January 2020 815-0006-01 Itron, Inc. Page 40 of 48