Itron recommends these Intelis Gas Meter Test Mode parameter settings when testing on the
Honeywell SNAP proving system:
Test Mode pulse weight: 0.25 CF
Test Mode pulse width: 150 ms
Tempering the Meter by Exercising
1. Log on to the prover as a Supervisor.
2. Select Special Functions.
3. Select Diagnostics (local).
08 July 2020 815-0154-00 REV 000 Itron, Inc. Page 20 of 66
Intelis Gas Meter Proving and Setup Guide
4 Proving the Intelis Gas Meter Using the Honeywell SNAP Proving
System